Leírás
FAST. FLEXIBLE. FUNCTIONAL.
The KATflow 150 is the premier product for flexibility and performance, providing the user with a comprehensive specification and a list of configuration options. The practical modular design and the wide variety of different transducer types available ensure this instrument is suitable for everything from simple water flow measurements to energy flow monitoring and automated process control.
The KATflow 150 is an advanced ultrasonic flowmeter for permanent installation. The dual-channel design allows the user to either save cost and time by performing two independent measurements simultaneously or to install two pairs of transducers on a single pipe for locations where there are non-ideal flow conditions. Where this is used the sum, difference, average and maximum calculations are available in order to provide further processing of the data.
HIGHLIGHTS
- Dual flow monitoring with sum, average, difference and maximum calculations
- Process outputs including current, open-collector, relay
- Communication options RS 485, Modbus RTU and HART* compatible output
- Current inputs for temperature, pressure and density compensation
- Up to 100,000 measurement data logger and software for sampling and data transfer
- Optional heat quantity (thermal energy) measurement functionality
* HART® is a registered trademark of the HART Communication Foundation
SPECIFICATIONS
- Pipe diameter range 10 mm to 6,500 mm
- Temperature range for sensors -30 °C to +250 °C (-22 °F to +482 °F), higher temperatures available on request
- Lockable and sturdy IP 66 polycarbonate flowmeter enclosure
- Selectable three-line LCD display and full keypad
- Measurement of two flows simultaneously
- Up to ten input or output slots available
APPLICATIONS
Manufacturing and Process | Cooling systems on injection moulding machines
Measurement of paint flows Fire pump control |
Water and Wastewater | Dual-pipe metering for cost saving
Replacement of large bore electromagnetic flowmeters Effluent metering |
Building Services | Installation on hot water lines
Dual-channel energy flow measurement Installation on chilled water systems |
Semiconductor | Demineralised water measurements
Control of hydrofluoric acid flows Measurement in clean room environment |
Pharmaceutical | Water for injection measurement
Measurement of sterile fluids Clean in process (CIP) system monitoring |
General Industry | Automated process control
Measurement of furnace cooling flows Fuel and oil consumption measurements |